The schematic of the pedestal generator is shown below. The adapted single-turn lumped inductance magnet is pulsed from
a 12-cells artificial Pulse Forming Network (PFN) generator via six parallel transmission cables. The PFN is positively charged
from a pulsed resonant power supply. The reflection generated by the L/R load, and the ensuing partial refusal of the
main switch thyratron to conduct, is largely absorbed by the filter at the switch cathode.