Meeting on Linac4 - PSB BI Line, 01-March-2010
Present: F. Roncarolo, U. Raich, C. Carli, C. Bracco, B. Goddard, J.
Borburgh, B. Balhan, R. Chamizo.
- Specification for BTV (slides BG)
- No major comments on the requirements presented
- CC said that PPM would be good if it could be possible.
- JB noted that this will affect the reliability, which is an important
design requirement.
- UR noted that aging effects should be considered - BG said that he would
add total expected dose to specification.
- FR asked whether this was to be combined with foil viewing - not obvious
and needs investigation.
- Multipole component in ramping BS magnets (slides JB)
- Study of effect of changing graphite resistivity ready in a week
or so.
Harmonic analysis of eddy current effects showed about 10-4 T at the 20mm
radius, with coefficient strength dropping with increasing order.
- Inhomogeneity from magnet geometry expected to be in 10-2 range, so can
consider this negligible.
- AOB
- H0/H- dump and monitor specifications circulating for comments.
- Failure cases for SMV and DIS - BG and CB to provide some input in 2
weeks, impact parameters and angles. Also investigate utility of DIS
scrapers.
- Analysis of failure case effects on SMV needs rough magnet geometry - JB
to provide to RC.
WW